Location

MWA Technology
MWA Technology Limited, Offices & Workshop,
2 Wharton Street Ind. Est., Birmingham, West Midlands, B7 5TR

+44 (0) 121 327 7771

X

Gas Dectection and Gas Proving

Electro Controls EGS gas detector

EGS\NG - CL
Electro Controls EGS gas detector available at MWA Technology
Speedy delivery from MWA Technology!

Order by

4:30pm on Monday

for guaranteed delivery on Tuesday!

Electro Controls

Electro Controls EGS gas detector

EGS\NG - CL
Request a Quote  

This range of gas detectors can be used to detect leaks and provide an alarm in general commercial and industrial applications.
Can be used stand alone, with a BMS system or with a monitor panel.

MWA Code Gas Range Relay set point
EGS-NG Nat Gas ( methane) 0 to 5,000ppm 2500ppm
EGS-LPG LP Gas 0 to 2,000ppm 1000ppm
EGS-CO Carbon monoxide 0 to 100ppm 30ppm
EGS-R134 Refrig R134 0 to 1000ppm 500ppm
EGS-H Hydrogen 0 to 2,000ppm 1000ppm
EGS-CO2/IR Carbon dioxide 0 to 10,000ppm 5000ppm
ECS-OZ Ozone 0-1ppm 0.2ppm
EGS-O Oxygen 0 to 25% 19%
EGS-H2S Hydrogen sulphide 0 to 30ppm 5ppm
EGS-SD Sulphur dioxide 0 to 10ppm 2ppm
EGS-ND Nitrogen dioxide 0 to 10ppm 3ppm
EGS-CL Chlorine 0 to 10ppm 0.5ppm
Top

Geca Residential and Commercial gas detectors

Geca Residential and Commercial gas detectors available at MWA Technology
Speedy delivery from MWA Technology!

Order by

4:30pm on Monday

for guaranteed delivery on Tuesday!

Gamma Residential Gas leak detector with optical acoustic alarm, control relay ,fixed sensor for LPG and natural gas.

Beta Residential Gas leak detector with optical acoustic alarm, control relay ,replaceable sensor for LPG and natural gas.

CTR21 Commercial gas control unit with incorporated sensors ,3 relay outputs ,test and reset function,for either LPG or natural gas

CTM21 Commercial gas control unit  suitable for one selectable sensor,3 relay outputs , test and reset function.

CTP21 Commercial gas control unit suitable for 3 selectable sensors,3 relay ouputs ,test and reset function

CTP23 Commercial gas control unit suitable for 3 zones with display,for 3 selectable sensors , 3 relay outputs,test and reset function

ST441 Gas sensor IP44 suitable for LPG or Natural Gas for CTM/CTP

SE183 Explosion proof gas sensor suitable for Natural Gas  Ex II 2G Ex IIC T5 Gb Cert CESI ATEX 030X

Top

Landon Kingsway 1000S Gas Proving System

1000S
Landon Kingsway 1000S Gas Proving System available at MWA Technology
Speedy delivery from MWA Technology!

Order by

4:30pm on Monday

for guaranteed delivery on Tuesday!

Landon Kingsway

Landon Kingsway 1000S Gas Proving System

1000S
Request a Quote  

The Merlin1000S gas pressure proving system is designed specifically for use with School and University Laboratories.

This panel is to used to carry out a gas pressure proving test on the pipework in order to highlight if there is a gas appliance open or a gas leak. in the laboratory.

The Merlin 1000S panel is designed to give full control over the incoming gas supply with a lockable key switch operation.

The panel can work in conjunction with carbon dioxide ,natural gas, Aarbon monoxide and LPG sensors.

The panel has a built in time out facility which will automatically shut off a solenoid valve at the end of a specific time period. which can be adjusted to a 2,5 or 8 hour period. This can overridden if required.

the gas supply valve is energised.

Technical Specification

  • Mains input 230V AC Single Phase
  • Gas solenoid valve power output 230v AC ,Max 3 Amp,EN161 approved.
  • BMS output contacts, common,. normally closed and normally open , Max 1 Amp @ 230v AC.
  • Gas pressure transducer ,power supply and returned signal..
  • Remote Emergency stop buttons and Fire alarm input wired in series- suppled separately .Volt free input
  • Methane ,Carbon Monoxide or LPG gas detectors ,power supply and volt free input – supplied separately.
  • Fan switch output – supplied separately.
  • CO2 monitor -supplied separately ,volt free input.
  • Permanent 12v DC output
  • Dimensions H178mm x L254mm x D62mm
Top

Landon Kingsway LKGDP2 Gas Detector Panel

LKGDP2
Landon Kingsway LKGDP2 Gas Detector Panel available at MWA Technology
Speedy delivery from MWA Technology!

Order by

4:30pm on Monday

for guaranteed delivery on Tuesday!

Landon Kingsway

Landon Kingsway LKGDP2 Gas Detector Panel

LKGDP2
Request a Quote  

Landon Kingsway GDP2 single or 2 zone gas detection for boiler houses ,plantrooms and factories . Suitable for Natural gas ,Carbon Monoxide and LPG.

Gas detectors are fixed and remote from the panel

Specifications:

230v AC input

Remote gas detectors 24v DC power supply – sold seperately

Remote emergency push buttons and thermal links can be connected to the panel

Remote gas solenoid valves can be connected to the panel.

Top

Landon Kingsway LKGDP4 Gas Detector Panel

LKGDP4
Landon Kingsway LKGDP4 Gas Detector Panel available at MWA Technology
Speedy delivery from MWA Technology!

Order by

4:30pm on Monday

for guaranteed delivery on Tuesday!

Landon Kingsway

Landon Kingsway LKGDP4 Gas Detector Panel

LKGDP4
Request a Quote  

The LKGSP4 is gas detection and shut off system that can be used for up to 4 gas detectors and is used in a variety of applications including boiler houses ,plantrooms and factories.

Suitable for a variety of gases including ; Natural gas, Carbon Monoxide or LPG.

Gas detectors are fixed remote from the panel and are wire back to panel and 3 core low voltage cable.

Technical Specifications

Supply Voltage 230V AC ,current 35 Ma , 8W
Operates EN161 gas solenoid valve 230v AC Max 3A
Remote gas detectors 24V DC input -Supplied seperately
Remote EM stop buttons and Fusible Links , volt free input

Sounder alarm 24v DC , 100Ma .

BMS output contacts , Normally closed, Common , Normally open.1Amp max

Weight 1.5 Kg

Temperature 0 – 50C

Size ,width 255mm x height 180mm x depth 77mm

Top

Landon Kingsway Severlek Emergency Button

Severlek
Landon Kingsway Severlek Emergency Button available at MWA Technology
Speedy delivery from MWA Technology!

Order by

4:30pm on Monday

for guaranteed delivery on Tuesday!

Landon Kingsway

Landon Kingsway Severlek Emergency Button

Severlek
Request a Quote  

The Landon Kingsway Severlek Emergency Button has a variety of uses where it is required to have a latching push button switch to sound an alarm or de-activate equipment. The switch has both a normally open and a normally closed contact pair which both change state on the switch being pressed. Enclosure Grey epoxy coated die-cast aluminium with red plastic button.

Dimensions: 89 x 71 x 95mm
Fixing centres: 74 x 57mm Ø8mm
Protection rating: IP65
Switch rating: 2KVA AC, 100W DC
Wire size: 2x 2.5mm²
Conduit Connection: PG16
Weight: 0.4kg

Available Models:
Manual Quick Release Mechanism
Electromek MK11 manual relese with 2X C/0 contacts
Sevelek Emergency Panic Button C/0 contacts
Kingsway Emergency Panic Button
Key Operated isolation Switch

Top

S&S Merlin CT500S safety panel

CT500S
S&S Merlin CT500S safety panel available at MWA Technology
Speedy delivery from MWA Technology!

Order by

4:30pm on Monday

for guaranteed delivery on Tuesday!

S&S Northern

S&S Merlin CT500S safety panel

CT500S
Request a Quote  

The key operated CT500S is UK manufactured and like all S & S Northern products carries a 3 Year warranty and is fully supported by our technical team. The CT500S has a fascia
mounted emergency shut off button fitted as standard and the fascia mounted LEDs give simple and concise information to the operator.

The panel is fully compatible with S & S Northern remote emergency stop terminals allowing a large number of emergency terminals to be connected in series and wired back to the panel.

Top

S&S Merlin FAB1 fire alarm bypass panel

FAB1
S&S Merlin FAB1 fire alarm bypass panel available at MWA Technology
Speedy delivery from MWA Technology!

Order by

4:30pm on Monday

for guaranteed delivery on Tuesday!

S&S Northern

S&S Merlin FAB1 fire alarm bypass panel

FAB1
Request a Quote  

With prior notice to a fire alarm test, the operator can turn the spring loaded key to the on position giving an un-interrupted gas supply for between 10 and 45 minutes.

During this time the system controlling the gas will ignore shut-off signals from the buildings fire alarm system and allow factors such as heating systems to remain operational.

Top

Added to basket!

Submit Enquiry Now

By continuing to use the site, you agree to the use of cookies. more information

The cookie settings on this website are set to "allow cookies" to give you the best browsing experience possible. If you continue to use this website without changing your cookie settings or you click "Accept" below then you are consenting to this.

Close