Turbine Gas Meters
A turbine gas meter is perfect for Secondary metering industrial applications where gas flow continuity is crucial.Using gas velocity for measuring the volume of gas within the meter, these inferential style meters measure the flow rates within the meter parameters.
Our range of turbine meters from Aichi ,Common, Itron are all, space saving, inline meters with a variety of options are available, including MID approved for Primary and Billing .Other options include MID volume converters, Biogas options with pulse, Mbus, Wireless Mbus and 4-20 Ma outputs to suit your application.
-
Aichi TBX low pressure drop digital turbine gas meters
-
Aichi TBZ low pressure drop digital turbine gas meters
-
Common CGT-02 MID Turbine gas meters
-
Common CPT-01 Quantometers – flange fitting
-
Common CPT-01 Quantometers – screwed fitting
-
Dresser Actaris Fluxi 2000/TZ MID Turbine Gas Meters
-
Dresser Actaris MZ Quantometers
-
Honeywell Elster QA Quantometers
-
Honeywell Elster TRZ2 Turbine Gas Meters
-
Nixon NTG Digital Turbine Air and Gas Meter
-
RMG TME 400 VC Digital Turbine meter with volume corrector
-
RMG Turbine gas meter for Hydogen
-
RMG Turbine meter TRZ 03
Aichi TBX low pressure drop digital turbine gas meters
Order in the next
for guaranteed delivery tomorrow!
The TBZ and TBX Series of turbine meters were developed to measure the gas consumption of small boilers, industrial furnaces, other individual pieces of equipment. The TBZ and TBX Series are precise and inexpensive — they are compact, light, and stylish too. They can handle a wide range of pressures and flows. Two built-in pulse oscillators allow remote meter-reading — or the configuration of an advanced energy management system.
- Inline meter takes up less space
- Self-supporting in pipework
- 50mm meter same output as 3inch diaphragm meter
- Maximum operating pressure 1.0 bar
MWA Code | Description | Fitting | Min m³/hr |
Max m³/hr |
---|---|---|---|---|
TBX30L-0.75 | Low pressure drop turbine meter | ¾” Screwed | 4 | 30 |
TBX30L-1.0 | Low pressure drop turbine meter | 1” Screwed | 4 | 30 |
TBX30L-1.25 | Low pressure drop turbine meter | 1¼” Screwed | 4 | 30 |
TBX30L-1.5 | Low pressure drop turbine meter | 1½” Screwed | 4 | 30 |
TBX100L-2.0 | Low pressure drop turbine meter | 2” Screwed | 10 | 100 |
TBX150F | Low pressure drop turbine meter | 2” /50mm Flanged PN16 | 7 | 150 |
TBX PLUG | TBX plug with 2 metre lead – 4 Pin Plug |
Aichi TBZ low pressure drop digital turbine gas meters
Order in the next
for guaranteed delivery tomorrow!
The TBZ Series even offers a temperature/pressure compensation capability — gas flow is converted to standard conditions for display.
The TBZ and TBX Series of gas meters were jointly developed by Tokyo Gas and Aichi Tokei Denki, leaders in energy management.
- Inline meter takes up less space
- Self-supporting in pipework
- 50mm meter same output as 3inch diaphragm meter
- Maximum operating pressure 9.0 bar
MWA Code | Description | Fitting | Min m³/hr |
Max m³/hr |
---|---|---|---|---|
TBZ60 | Turbine Meter Turbine Meter | 1½” Flanged PN16 | 3 | 60 |
TBZ150 | Low pressure drop turbine meter | 2” Flanged PN16 | 7.5 | 150 |
TBZ300 | Low pressure drop turbine meter | 3” Flanged PN16 | 15 | 300 |
TBZ150KIT | Kit PN6 50mm flanges, gaskets, BZP M16 bolts and nuts | |||
TBZ300KIT | PN6 80mm Flanges, Gaskets & BZP M16 Bolts & Nuts | |||
TBZPULSE | TBZ300 plug with 2 metre lead – 3 Pin Plug |
Common CGT-02 MID Turbine gas meters
Order in the next
for guaranteed delivery tomorrow!
- Fitted with low frequency pulse output as standard
- Flanged PN16 connection
- Cast Iron or Carbon Steel, suitable for natural gas and LPG -20 to 60C
- Inline turbine gas meters with flanged PN16 connections, PN25, PN40, ANSI 150, 300.600.
- For horizontal or vertical pipelines with 2 x DN straight lengths
- Rangeability 1:20, Meters read in cubic metres, index can be head rotated through 360 deg
MWA Code | Size | Max Pressure | Min m³/hr |
Max m³/hr |
---|---|---|---|---|
CGT50G40 | 2″ | 16 bar | 6 | 65 |
CGT50G65 | 2″ | 16 bar | 10 | 100 |
CGT80G100 | 3″ | 16 bar | 8 | 160 |
CGT80G160 | 3″ | 16 bar | 13 | 250 |
CGT80G250 | 3″ | 16 bar | 20 | 400 |
CGT100G160 | 4″ | 16 bar | 13 | 250 |
CGT100G250 | 4″ | 16 bar | 20 | 400 |
CGT100G400 | 4″ | 16 bar | 32 | 650 |
CGT100G250 | 4″ | 16 bar | 20 | 400 |
CGT100G400 | 4″ | 16 bar | 32 | 650 |
CGT150G400 | 6″ | 16 bar | 32 | 650 |
CGT150G650 | 6″ | 16 bar | 50 | 1000 |
CGT150G1000 | 6″ | 16 bar | 80 | 1600 |
CGT200G650 | 8″ | 16 bar | 50 | 1000 |
CGT200G1000 | 8″ | 16 bar | 80 | 1600 |
CGT200G1600 | 8″ | 16 bar | 130 | 2500 |
CGT250G1000 | 10″ | 16 bar | 80 | 1600 |
CGT250G1600 | 10″ | 16 bar | 130 | 2500 |
CGT250G2500 | 10″ | 16 bar | 200 | 4000 |
CGT300G1600 | 12″ | 16 bar | 130 | 2500 |
CGT300G2500 | 12″ | 16 bar | 200 | 4000 |
CGT300G4000 | 12″ | 16 bar | 320 | 6500 |
CGT calibration certificates | |
---|---|
CGT Encoder 4 -20 Ma or Mbus output | |
CGT 6 pin pulse plug and 2 metre lead | |
CGT high frequency pulse outut -external | |
CGT high frequency pulse outut -internal | |
CGT Remote 6 digit single LCD display installed in IP65 ABS enclosure -resettable | |
CGT Remote 2 X 6 digit twin LCD display installed in IP65 ABS enclosure -resettable | |
CGT Remote 3 x 6 digit single LCD display installed in IP67 enclosure | |
CGT Remote 6 digit single LCD display Programmable installed in IP67 enclosure | |
CGT Dresser Chatterbox – e.Model 103 Opto -isolation unit,battery operated ,4 outputs, Atex IS | |
CGT Relay Padplus pulse to Mbus converter | |
CGT CMK-03 pressure and temperature volume corrector |
Common CPT-01 Quantometers – flange fitting
Order in the next
for guaranteed delivery tomorrow!
CPT Quantometers have been designed in order to provide our customers with reliable and inexpensive measuring instruments for secondary flows.
- Inline turbine gas meters with wafer connections to suit PN16 flanges
- Fitted with low frequency pulse output as standard – multiple LF & HF options available
- Aluminium body, suitable for natural gas and LPG, -20°C to +60°C
- Biogas option available, filter recommended for this media.
- For horizontal or vertical pipelines with 5 x DN straight lengths of pipe up stream
- Nominal rangeability 1:20, meters read in cubic metres, index can be head rotated through 350°
MWA Code | Size | Connections | Pulse Values | Max pressure | Min m³/hr |
Max m³/hr |
Weight |
---|---|---|---|---|---|---|---|
CPT50G40* | 50mm | wafer for PN16 | Pulse output, 1 pulse = 0.1 m³/hr | 16 bar | 6 | 65 | 3.6kg |
CPT50G65* | 50mm | wafer for PN16 | Pulse output, 1 pulse = 0.1 m³/hr | 16 bar | 10 | 100 | 3.6kg |
CPT65G65* | 65mm | wafer for PN16 | Pulse output, 1 pulse = 0.1 m³/hr | 16 bar | 8 | 100 | 5.3kg |
CPT65G100 | 65mm | wafer for PN16 | Pulse output, 1 pulse = 1 m³/hr | 16 bar | 8 | 160 | 5.3kg |
CPT80G100 | 80mm | wafer for PN16 | Pulse output, 1 pulse = 1 m³/hr | 16 bar | 8 | 160 | 5.3kg |
CPT80G160 | 80mm | wafer for PN16 | Pulse output, 1 pulse = 1 m³/hr | 16 bar | 13 | 250 | 5.3kg |
CPT80G250 | 80mm | wafer for PN16 | Pulse output, 1 pulse = 1 m³/hr | 16 bar | 20 | 400 | 5.3kg |
CPT100G160 | 100mm | wafer for PN16 | Pulse output, 1 pulse = 1 m³/hr | 16 bar | 13 | 250 | 7.4kg |
CPT100G250 | 100mm | wafer for PN16 | Pulse output, 1 pulse = 1 m³/hr | 16 bar | 20 | 400 | 7.4kg |
CPT100G400 | 100mm | wafer for PN16 | Pulse output, 1 pulse = 1 m³/hr | 16 bar | 32 | 650 | 7.4kg |
CPT150G400 | 150mm | wafer for PN16 | Pulse output, 1 pulse = 1 m³/hr | 16 bar | 32 | 650 | 11.6kg |
CPT150G650 | 150mm | wafer for PN16 | Pulse output, 1 pulse = 1 m³/hr | 16 bar | 50 | 1000 | 11.6kg |
CPT150G1000 | 150mm | wafer for PN16 | Pulse output, 1 pulse = 10 m³/hr | 16 bar | 80 | 1600 | 11.6kg |
CPT200G650 | 200mm | wafer for PN16 | Pulse output, 1 pulse = 1 m³/hr | 16 bar | 50 | 1000 | 51kg |
CPT200G1000 | 200mm | wafer for PN16 | Pulse output, 1 pulse = 10 m³/hr | 16 bar | 80 | 1600 | 51kg |
CPT200G1600 | 200mm | wafer for PN16 | Pulse output, 1 pulse = 10 m³/hr | 16 bar | 80 | 2500 | 51kg |
* Rangeability 1:10
Options
CPT calibration certificates |
CPT Encoder 4-20 Ma or Mbus output |
CPT 6-pin pulse plug and 2 metre lead |
CPT high-frequency pulse output – external |
CPT high-frequency pulse output – internal |
CPT Remote 6-digit single LCD display Programmable installed in IP67 enclosure |
CPT Chatterbox – e.Model unit, battery operated, 4 outputs, Atex IS. |
Common CPT-01 Quantometers – screwed fitting
Order in the next
for guaranteed delivery tomorrow!
CPT Quantometers have been designed in order to provide our customers with reliable and inexpensive measuring instruments for secondary flows.
- pressure resistant meter body
- inlet flow conditioner
- measuring cartridge and index head
- magnetic coupling as the transferring elementbetween measuring
- range extended to include 1 inch,1.¼ inch, 1.½ inch, 2 inch screwed options
- meter for Biogas available ,filter recommended for this media.
- Atex approved index head
- meter tested to 2004/22/EC MID, Annex-MI-002 Class;1.5
MWA Code | Size | Connection | QMin m³/hr |
QMax m³/hr |
---|---|---|---|---|
CPT25SG16 | 25mm | Screwed | 2.5 | 25 |
CPT25SG25 | 25mm | Screwed | 4 | 40 |
CPT32SG25 | 32mm | Screwed | 4 | 40 |
CPT40SG40 | 40mm | Screwed | 6 | 65 |
CPT40SG65 | 40mm | Screwed | 10 | 100 |
CPT50SG40 | 50mm | Screwed | 6 | 65 |
CPT50SG65 | 50mm | Screwed | 10 | 100 |
Recommended accessories
MWA Code | Description |
---|---|
CPTPLUG | CPT Plug and pulse lead (2 meters) |
FM25 | 25mm inline filer (50 micron) |
FM32 | 32mm inline filer (50 micron) |
FM40 | 40mm inline filer (50 micron) |
FM50 | 50mm inline filer (50 micron) |
Dresser Actaris Fluxi 2000/TZ MID Turbine Gas Meters
Order in the next
for guaranteed delivery tomorrow!
Dresser Actaris Flanged Turbine Gas Meter for Primary and Secondary Metering. Traceability to PTB standards.
Applications
Dresser Actaris Fluxi 2000/TZ meters are designed to measure natural gas, and various filtered, and non-corrosive gases. They are used to measure medium to high gas flow, at low, medium or high pressure. The Fluxi 2000/TZ meters have been optimised for use in all applications related to the transportation and distribution of gas. Fluxi 2000/TZ meters are approved for fiscal use.
Basic Features
- PTB approved with only 2 DN inlet straight pipe, 0 (zero) DN outlet pipe even with severe perturbations
- MID approved
- Go beyond compliance with all current European and International Standards
- Reduced pressure loss for low pressure network
- Excellent high-pressure behaviour
- IP 67 protection of the totaliser
- Equipped as standard with the cyble target for ;
- Cyble pulse unit,Cyble Atex pulse unit,Cyble Mbus unit
- Various options available: integrated thermowells, oil pump, pulse transmitters, etc.
Technical Specifications | |
Metrological Approvals | Compliant with the Measuring Instrument Directive 2004/22/EC | Approval number: DE-10-MI002-PTB001 |
Intrinsic Safety Approval | Compliant with the Directive 94/9/EC | Approval Number: LCIE 06 ATEX 6031 X |
Flow Rate | From 5 m³/h to 10000 m³/h, G65 to G6500 |
Nominal Diameters | From DN50 to DN400 mm (2″ to 16″) |
Maximum Working Pressure | Up to 100 bar depending on the body material and flanging |
Mounting | The Fluxi 2000/TZ meters can be installed either horizontally or vertically, for the DN50 to DN300, and horizontally for the DN400 |
Body Materials | Ductile iron, cast steel or welded steel. Compliant with the Pressure Equipment Directive 97/23/EC |
Temperature Range | ATEX/PED: -30°C to +60°C MID: -25°C to +55°C Storage temperature: -40°C to +70°C |
MWA Code | Description | Body Length |
---|---|---|
TZDN50G65 | Dresser Actaris. DN50 Flanged Turbine Gas Meter Qmin 5 m³/h Qmax 100 m³/h PN16 | 150mm |
TZDN80G100 | Dresser Actaris. DN80 Flanged Turbine Gas Meter Qmin 8 m³/h Qmax 160 m³/h PN16 | 240mm |
TZDN80G160 | Dresser Actaris. DN80 Flanged Turbine Gas Meter Qmin 13 m³/h Qmax 250 m³/h PN16 | 240mm |
TZDN80G250 | Dresser Actaris. DN80 Flanged Turbine Gas Meter Qmin 20 m³/h Qmax 400 m³/h PN16 | 240mm |
TZDN100G160 | Dresser Actaris. DN100 Flanged Turbine Gas Meter Qmin 13 m³/h Qmax 250 m³/h PN16 | 300mm |
TZDN100G250 | Dresser Actaris. DN100 Flanged Turbine Gas Meter Qmin 20 m³/h Qmax 400 m³/h PN16 | 300mm |
TZDN100G400 | Dresser Actaris. DN100 Flanged Turbine Gas Meter Qmin 32 m³/h Qmax 650 m³/h PN16 | 300mm |
TZDN150G400 | Dresser Actaris. DN150 Flanged Turbine Gas Meter Qmin 32 m³/h Qmax 650 m³/h PN16 | 450mm |
TZDN150G650 | Dresser Actaris. DN150 Flanged Turbine Gas Meter Qmin 50 m³/h Qmax 1000 m³/h PN16 | 450mm |
TZDN150G1000 | Dresser Actaris. DN150 Flanged Turbine Gas Meter Qmin 50 m³/h Qmax 1000 m³/h PN16 | 450mm |
TZDN200G650 | Dresser Actaris. DN200 Flanged Turbine Gas Meter Qmin 50 m³/h Qmax 1000 m³/h PN16 | 600mm |
TZDN200G1000 | Dresser Actaris. DN200 Flanged Turbine Gas Meter Qmin 80 m³/h Qmax 1600 m³/h PN16 | 600mm |
TZDN200G1600 | Dresser Actaris. DN200 Flanged Turbine Gas Meter Qmin 130 m³/h Qmax 2500 m³/h PN16 | 600mm |
TZDN250G1000 | Dresser Actaris. DN250 Flanged Turbine Gas Meter Qmin 80 m³/h Qmax 1600 m³/h PN16 | 750mm |
TZDN250G1600 | Dresser Actaris. DN250 Flanged Turbine Gas Meter Qmin 130 m³/h Qmax 2500 m³/h PN16 | 750mm |
TZDN250G2500 | Dresser Actaris. DN250 Flanged Turbine Gas Meter Qmin 200 m³/h Qmax 4000 m³/h PN16 | 750mm |
TZDN300G1600 | Dresser Actaris. DN300 Flanged Turbine Gas Meter Qmin 130 m³/h Qmax 2500 m³/h PN16 | 900mm |
TZDN300G2500 | Dresser Actaris. DN300 Flanged Turbine Gas Meter Qmin 200 m³/h Qmax 4000 m³/h PN16 | 900mm |
TZDN300G4000 | Dresser Actaris. DN300 Flanged Turbine Gas Meter Qmin 320 m³/h Qmax 6500 m³/h PN16 | 900mm |
TZDN400G2500 | Dresser Actaris. DN400 Flanged Turbine Gas Meter Qmin 200 m³/h Qmax 4000 m³/h PN16 | 1200mm |
TZDN400G4000 | Dresser Actaris. DN400 Flanged Turbine Gas Meter Qmin 320 m³/h Qmax 6500 m³/h PN16 | 1200mm |
TZDN400G6500 | Dresser Actaris. DN400 Flanged Turbine Gas Meter Qmin 500 m³/h Qmax 10000 m³/h PN16 | 1200mm |
TZDN500G4000 | Dresser Actaris. DN500 Flanged Turbine Gas Meter Qmin 320 m³/h Qmax 6500 m³/h PN16 | 1500mm |
TZDN500G6500 | Dresser Actaris. DN500 Flanged Turbine Gas Meter Qmin 500 m³/h Qmax 10000 m³/h PN16 | 1500mm |
Dresser Actaris MZ Quantometers
Order in the next
for guaranteed delivery tomorrow!
Dresser Actaris turbine gas MZ meters are suitable for both natural gas and other filtered and non-corrosive gases. They are used to measure low to medium and high flow, at low or medium, or high pressure. Various additional fitting options are available including an oil pump and a PTFE coating version, making them also suitable for heavy duty measurement.
Biogas versions available, filter recommended for this media..
- Turbine sizes: 50mm to 200mm
- Flow rate: from 6m³/h to 2500m³/h
- Dn 250 to 400mm options
- Wafer type 50mm to 80mm, 100mm above PN16 gas
- Flanging options: ISO PN10 to ISO PN110, ANSI 150 to ANSI 600
- Cyble pulse unit, Cyble Atex pulse unit, Cyble Mbus unit
MWA Code | Size | Output | Min m³/hr |
Max m³/hr |
---|---|---|---|---|
MZ50G65 | 50mm | Pulse | 6 | 100 |
MZ80G160 | 80mm | Pulse | 16 | 250 |
MZ80G250 | 80mm | Pulse | 25 | 400 |
MZ100G250 | 100mm | Pulse | 25 | 400 |
MZ100G400 | 100mm | Pulse | 40 | 650 |
MZ150G650 | 150mm | Pulse | 65 | 1000 |
MZ150G1000 | 150mm | Pulse | 100 | 1600 |
MZ200G1000 | 200mm | Pulse | 100 | 1600 |
MZ200G1600 | 200mm | Pulse | 160 | 2500 |
Honeywell Elster QA Quantometers
Order in the next
for guaranteed delivery tomorrow!
Honeywell Elster Quantometers are highly reliable gas meters which meet the highest standards. By using the quantometers in production and heating processes, it is possible to control flow of gas precisely and therefore optimise the use of energy. They work on the principle of the rotating turbine wheel. The rotation of the turbine wheel is proportional to the volume of the flowing gas.
Features & Benefits
- DVGW – approved.
- Compact in size.
- High reliability & standards.
- Optional pulse output facility.
- Suitable for various gases.
Technical Data
- Rangeability: up to 1:20
- Flow ranges: 1.6 -1,600 m³/h (56 – 56,000 ft³/h)
- Diameters: DN 25 – 150
- Pressure rates: PN 4, PN 16, ANSI 150
- Gas temperature QA: -10°C to +60°C (14° to 140°F)
- Ambient temperature QA: -20°C to +70°C (-4° to 158°F)
- Ambient- / gas temperature QAe: 0°C to +50°C (32° to 122°F)
MWA Code | Size | Min m³/hr |
Max m³/hr |
|
---|---|---|---|---|
QA10 DN25 | 25mm | 1.6 | 16 | |
QA16 DN25 | 25mm | 2 | 25 | |
QA25 DN25 | 25mm | 2.5 | 40 | |
QA40 DN25 | 25mm | 3.3 | 65 | |
QA40 DN40 | 40mm | 5 | 65 | |
QA65 DN 50 | 50mm | 6 | 100 | |
QA100 DN 80 | 80mm | 10 | 160 | |
QA160 DN 80 | 80mm | 13 | 250 | |
QA250 DN 100 | 100mm | 20 | 400 | |
QA400 DN 100 | 100mm | 32 | 650 | |
QA650 DN 150 | 150mm | 50 | 1000 |
Honeywell Elster TRZ2 Turbine Gas Meters
Order in the next
for guaranteed delivery tomorrow!
Honeywell Elster – Instromet TRZ2 turbine gas meters are robust meters for use in stationary conditions. Over years they have proved themselves to be highly accurate and reliable devices for measuring the flow of gaseous substances. With the patented Honeywell Elster – Intromet measuring cartridge it is possible to save service time by replacement of the cartridge on site.
The measuring cartridge is supported with O-rings, is free of tension and is, therefore, not affected by any influences stemming from the housing or the ambient conditions such as temperature fluctuations.
Key Features
- Turbine gas meters with measuring cartridge
- Aluminium flow straightener DN80 – 150
- Meter Types: G 65 – 1000
- Flow Range: 5 – 1600m3/h
- Diameters: DN50* – 150 (2″ – 6″)
- Pressure rates: PN10 – 100, ANSI 150 – 600
- Temperature Range: MID -25°C to +55°C, PED -25°C to +55°C (steel), ATEX -20°C to +60°C
- Manual oil pump (standard for PN25 – 100 and ANSI 300 – 600)
- Compact installation, inlet pipe length L ≥ 2DN
- Length 3DN
- Thermowell built into meter housing (optional)
- Inegrated HF-pulser (optional)
- Absolute-ENCODER S1 (optional)
- EC, MID as well as different national approvals
- Media: Natural gas, petroleum gas, town gas, nitrogen, argon, further gases on request
MWA Code | Description | Body Length |
---|---|---|
TRZDN50G65 | Honeywell Elster. DN50 Flanged Turbine Gas Meter Qmin 5 m³/h Qmax 100 m³/h PN16 | 150mm |
TRZDN80G100 | Honeywell Elster. DN80 Flanged Turbine Gas Meter Qmin 8 m³/h Qmax 160 m³/h PN16 | 240mm |
TRZDN80G160 | Honeywell Elster. DN80 Flanged Turbine Gas Meter Qmin 13 m³/h Qmax 250 m³/h PN16 | 240mm |
TRZDN80G250 | Honeywell Elster. DN80 Flanged Turbine Gas Meter Qmin 20 m³/h Qmax 400 m³/h PN16 | 240mm |
TRZDN100G160 | Honeywell Elster. DN100 Flanged Turbine Gas Meter Qmin 13 m³/h Qmax 250 m³/h PN16 | 300mm |
TRZDN100G250 | Honeywell Elster. DN100 Flanged Turbine Gas Meter Qmin 20 m³/h Qmax 400 m³/h PN16 | 300mm |
TRZDN100G400 | Honeywell Elster. DN100 Flanged Turbine Gas Meter Qmin 32 m³/h Qmax 650 m³/h PN16 | 300mm |
TRZDN150G250 | Honeywell Elster. DN150 Flanged Turbine Gas Meter Qmin 20 m³/h Qmax 400 m³/h PN16 | 450mm |
TRZDN150G400 | Honeywell Elster. DN150 Flanged Turbine Gas Meter Qmin 32 m³/h Qmax 650 m³/h PN16 | 450mm |
TRZDN150G650 | Honeywell Elster. DN150 Flanged Turbine Gas Meter Qmin 50 m³/h Qmax 1000 m³/h PN16 | 450mm |
TRZDN150G1000 | Honeywell Elster. DN150 Flanged Turbine Gas Meter Qmin 80 m³/h Qmax 1600 m³/h PN16 | 450mm |
Nixon NTG Digital Turbine Air and Gas Meter
Order in the next
for guaranteed delivery tomorrow!
The Nixon range of turbine flow meters offers high accuracy and high reliability. Available in a wide variety of body sizes and styles, all NTG flow meters possess an electrical pulse output directly proportional to flow rate, based upon the operating principle described in this publication. Remote flow rate indication, alarms, totalising and batch control functions are available utilising our wide range of secondary electronic instruments.
Standard end connections are screwed BSP parallel thread with included 30 degree internal cones to BS5200, but Ermeto threads are also available. Flanged meters are normally to ANSI 150 or BS4504 (DIN) standards, but older type flanges to BS10 tables D-H may also be fitted. A unique feature of the design is the use of helically milled rotors cut from solid in sizes up to 65mm.
Bearing bushes are of PTFE/Carbon HY49 or similar, or tungsten carbide depending upon the nature of the metered fluid. In all cases, the spindle is of tungsten carbide with Cobalt binder, and thrust balls of tungsten carbide. Stainless steel ball races are used in the smaller sizes. The electrical signal is a sinusoidal pulse of minimum height 50mV peak at lowest flow rate, rising to 800mV peak at max flow rate. For normal transmission distances pre-amplifiers are not essential since pulse shaping and conditioning are carried out in the appropriate electronic readout unit.
In cases where heavy electrical noise is present or where transmission distances are over 500 metres, pre-amplifiers of standard or intrinsically safe design are available as head mounted weatherproof units and loop powered.
NTG Industrial Flow Meters for Air and Gas
- Temperature range -30°C to 150°C (400°C special design)
- Horizontal or vertical mounting
- Upto 500m transmission without pre-amplifiers
MWA Code | Fitting | Minlts/min | Maxlts/min |
---|---|---|---|
NTG3 | ⅜” Screwed | 0.5 | 5 |
NTG5 | ½” Screwed | 1.2 | 10 |
NTG7 | ½” Screwed | 2 | 20 |
NTG11 | ½” Screwed | 5 | 50 |
NTG13 | ¾” Screwed | 8 | 80 |
NTG19 | 1” Screwed | 15 | 150 |
NTG24 | 1” Screwed | 25 | 250 |
NTG32 | 1¼” Screwed | 45 | 450 |
NTG38 | 1½” Screwed | 65 | 650 |
NTG48 | 2” Screwed | 110 | 1100 |
NTG65 | 3” Screwed | 200 | 2000 |
NTG80 | 3” Flanged | 300 | 3000 |
NTG100 | 4” Flanged | 500 | 5000 |
NT150 | 6” Flanged | 1000 | 10000 |
RMG TME 400 VC Digital Turbine meter with volume corrector
Order in the next
for guaranteed delivery tomorrow!
RMG turbine meter TME 400 VC | ||||||||
The TME400 VC turbine meter is a flow meter suitable for gas measurement to comply with EN12261 ,EN 12405 and OIML. | ||||||||
Electronic totalizer which can display actual flow rate ,complete with pressure and temperature volume corrector. | ||||||||
Available with LF low frequency and HF high frequency output. Ex ib IIC T6 ,Zone 1, RS485 Modbus and 4-20 Ma | ||||||||
Battery operated 6 years or external power for Modbus | ||||||||
Meter head IP65 Atex II 2G Ex ia IIC T4 Gb | ||||||||
Temperature sensor fitted | ||||||||
MID Measuring range standard 1 . 20 up to 160 possible . | ||||||||
Flanged PN16 Standard ,Options up to PN40,ANSI300 | ||||||||
Temperature -25C to + 55C | ||||||||
Pressure connection standard for pressure transmitter 0.6 to 6.0 bara standard | ||||||||
Materials – body cast iron or cast steel, Delrin and Aluminium rotors | ||||||||
Accuracy MID | ||||||||
Size | Max flow m3/h | Min flow m3/h | Pulse value m3/h | |||||
50mm | 100 | 5 | 0.1 | |||||
80mm | 160,250,400 | 8, 12.5 , 20 | 1 | |||||
100mm | 250,400,650 | 12.5,20,32 | 1 | |||||
150mm | 650 ,1000,1600 | 32,50,80 | 1,1,10 | |||||
200mm | 1600 ,2500 | 80,125 | 10 | |||||
250mm | 1600 ,2500 , 4000, | 80,125,200 | 10 | |||||
300mm | 4000 ,6500, | 200,320 | 10 | |||||
RMG Turbine gas meter for Hydogen
Order in the next
for guaranteed delivery tomorrow!
The TRZ03 Turbine gas meter is suitable for natural gas and hydrogen.
Measurement in compliance with EN12261 and OIML
MID approval T10417
Low Frequency output in the meter head with High Frequency pulse output
Protection IP65
Standard Measuring range 1:20 ,Options up to 1:160
Pipe size 50 to 200mm PN16,PN40 option.ANSI 150,300,600 option
The pulse transmitters are intrinsically safe Ex ib IIC T6 suitable for Zone 1.
Pressure connection for PTZ volume corrector ERZ 2000
Accuracy +/- 1% Q min to 0.2 Q max,0.5% for 0.2 Q max to Q max
RMG Turbine meter TRZ 03
Order in the next
for guaranteed delivery tomorrow!
RMG turbine meter TRZ03 | |||||||
The TRZ 03 turbine meter is a flow meter suitable for gas measurement to comply with EN12261 and OIML. | |||||||
Available with LF low frequency and HF high frequency output Atex .Ex ib IIC T6 ,Zone 1 | |||||||
Meter head IP65 | |||||||
Thermowells inside meter – option | |||||||
MID Measuring range standard 1 . 20 (up to 160 possible) . | |||||||
Flanged PN16 Standard ,Options up to PN100,ANSI600 | |||||||
Temperature -25C to + 55C | |||||||
Pressure connection standard for pressure transmitter | |||||||
Materials – body cast iron or cast steel, Delrin and Aluminium rotors | |||||||
Accuracy MID | |||||||
Size | Max flow m3/h | Min flow m3/h | Pulse value m3/h | ||||
50mm | 100 | 5 | 0.1 | ||||
80mm | 160,250,400 | 8, 12.5 , 20 | 1 | ||||
100mm | 250,400,650 | 12.5,20,32 | 1 | ||||
150mm | 650 ,1000,1600 | 32,50,80 | 1,1,10 | ||||
200mm | 1600 ,2500 | 80,125 | 10 | ||||
250mm | 1600 ,2500 , 4000, | 80,125,200 | 10 | ||||
300mm | 4000 ,6500, | 200,320 | 10 | ||||
400mm | 6500 , 10000 | 320,500 | 10 | ||||
500mm | 10000 , 16000 | 500,800 | 10 , 100 | ||||
600mm | 16000 , 25000, | 800 ,1250 | 10 ,100 | ||||